タイトル: | Expansion of Stent and Lumen Diameters on Follow-up after Carotid Artery Stenting in Patients with Carotid Artery Stenosis. |
その他のタイトル: | 頸動脈狭窄に対する自己拡張型ステント留置後フォローアップ時のステント径と内腔の検討 |
著者: | Fujimoto, Kenta Hashimoto, Hiroyuki Nishiguchi, Mitsuhisa Inui, Toshitaka Tani, Naoki Horiuchi, Kaoru Chatani, Megumi Matsuoka, Ryuta Yaegaki, Takahide Nakagawa, Ichiro Nakase, Hiroyuki |
キーワード: | carotid artery stenting self-expansion plaque |
発行日: | 2017年2月 |
出版者: | The Japanese Society for Neuroendovascular Therapy |
引用: | Journal of Neuroendovascular Therapy Vol.11 No.2 p.65-75 (2017 Feb) |
抄録: | Purpose: We examined postoperative stent and lumen expansions after carotid artery stenting (CAS) in patients with carotid artery stenosis. Furthermore, we investigated factors influencing the stent and lumen expansions in a follow-up period. Subjects: 134 cases (128 patients) who underwent CAS and performed follow-up cerebral angiography 12 months after CAS were enrolled into this study. The stenosis rate based on the stent and lumen diameters on follow-up angiography as a percentage of that immediately after CAS was evaluated. Results: Both the stent and lumen diameters were significantly dilated 12 months after CAS (p <0.001). There were no significant stent-type-related differences in the stent expansion rate. In the symptomatic stenosis group, this expansion rate was significantly higher than in the asymptomatic stenosis group (p = 0.02). With respect to the presence or absence of a high signal intensity on time of flight (TOF) magnetic resonance (MR) images, the stent expansion rate was significantly higher in the high signal intensity group (p = 0.006). In patients with a plaque/sternocleidomastoid muscle signal intensity ratio of ≥1.50 on plaque images, it was significantly higher than in those with a value of <1.50 (p = 0.006). However, there were no significant differences in the lumen expansion rate among the groups. Conclusion: Both the stent and vascular lumen were dilated 12 months after CAS. Plaque fragility influenced the stent expansion rate; however, there were no significant factor-related differences in the vascular lumen expansion rate. |
内容記述: | 博士(医学)・乙第1414号・平成30年3月15日 ©2017 The Editorial Committee of Journal of Neuroendovascular
Therapy. All rights reserved. This is an open access article distributed under the terms of Creative Commons Attribution License(CC BY-NC-ND 4.0) https://creativecommons.org/licenses/by-nc-nd/4.0/. |